Longden Company has completed a 21,000 square foot data center expansion for EdgeConneX in Billerica, MA. This 30” high Concore 1250 access floor system includes underfloor air distribution cooling as well as underfloor power & data. This new space allows for continued growth of the EdgeConneX ‘Edge Data Center’ capabilities including future tenant racks, cages and expanded cooling capacity. The high pressure laminate finish allows for increased durability and low static generation. read more

Longden Completes Raised Flooring System for New Balance Headquarters

Longden Completes Raised Flooring System for New Balance Headquarters

Longden Company recently installed over 180,000 square feet of raised access flooring system for footwear manufacturer New Balance at their new headquarters in Brighton, MA.  In addition to providing the ultimate flexibility in office reconfiguration, the underfloor space will be utilized for HVAC, power, and telecom utility distribution.  Bare ConCore 1000 and 1500 panels were installed in the office and utility areas respectively.  The office areas were covered with carpet tile and the utility areas with VCT.  Longden lowered the flooring system in the bathrooms to accommodate underlayment and ceramic tile.  A unique feature in the office area was the installation of a rubber track to mimic an indoor running track.  Longden also provided and installed prefinished wood veneer panels to highlight the planned showroom areas. read more

Improved Comfort and Air Quality Using Underfloor Air Distribution

2

The use of raised access flooring provides great flexibility in reconfiguring office spaces due to changes in staffing or the introduction of new technology and equipment.  This flexibility is enhanced when underfloor utility distribution is included.  Underfloor Air Distribution (UFAD) not only increases configuration flexibility but also provides improved air quality and comfort for the inhabitants of the space.
In a traditional overhead air distribution system, the air is being fed from, and returned to, ductwork located in the ceiling.  The flow of air down into the space is met by the natural tendency of warmer air to rise up towards the ceiling.  This creates a turbulent zone where fresh air and stale air are mixed, resulting in lower quality air at the occupants level.  In periods where cooling is necessary, the supply air temperature needs to be lowered significantly below the desired temperature in order to compensate for this mixing and heating. read more

Access Flooring Finish Options

Basic

Having initially been created for use in computing environments, access flooring panels are often thought of as being monolithic and utilitarian in appearance.  However, because of energy savings, improved air quality, and flexible configurations, access flooring has enjoyed ever-increasing use in traditional office environments.  In these environments, floor finishes play a major role in creating the desired look and “feel” of the space and, as such, architects and designers look for multiple options. read more